Pneumatic angle seat valve

Stainless steel welding pneumatic angle seat valve

Click the image for a larger viewStainless steel welding pneumatic angle seat valve
  • Body materialSS304,SS316,SS316L
    Seal materialF46
    Nominal pressure1.6MPa
    Valve structureY-type
    Control typeSingle acting normally closed, normally open, double acting
    Temperature rangeF46:-30~220 Degrees
    Applicable mediumWater, oil, gas,steam,etc
    Optional accessorySolenoid valve, limit switch box, positioner, handle wheel, etc
Product parametersWorking principlePneumatic accessory

Standard technical parameters


Body material:304316316L

Spool material: 304316316L

Seat material: PTFE F46

Nominal size: DN15-DN80mm

Applicable temperature: PTFE:-30180

F46: -30220

Actuator must be used stainless steel material

Ambient temp.:-3080

Nominal pressure: 1.6Mpa

Connection type: Welding

Design standard: GB, ANSI, DIN, ISO

Control type: Single acting, air to open type

Single acting, air to close type

Double acting

Actuator material: Polyamide PA, stainless steel

Optional accessory: Solenoid valve, limit switch box, positioner, etc.




Welding pneumatic angle seat valve

Outline size drawing:



Type specification table:


Size

Inch

Welding connection

B

L

L1

L2

H

DN15

1/2’

15

155

100

62

120

DN20

3/4’

20

160

120

62

130

DN25

1’

25

185

140

76

160

DN32

1-1/4’

35

215

155

76

195

DN40

1-1/2’

38

225

170

76

245

DN50

2’

48

290

190

96

295

DN65

2-1/2

68

350

220

114

325

DN80

3

80

380

250

114

360





Size

Inch  

Inner diameter  

Kv Value  

The max. pressure differential

Air supply

The cylinder bore  

Flow direction



DN10

3/8’

10

3.7

0-16bar

4-7bar

50

Steam, gas,

Flow above seat


DN15

1/2’

15

4.2

50


DN20

3/4’

20

8.0

50


DN25

1’

25

19.0

63


DN32

1-1/4’

32

27.5

63


DN40

1-1/2’

40

42.0

63

Liquids, gas

Water hammer-free

Flow below seat


DN50

2’

50

55.0

80


DN65

2-1/2’

65

90

100


DN80

3

80


100


DN100

4

100


125


Pneumatic actuator working principle




Control mode:

 

According to the site condition has the following three kinds of control mode, the reasonable selection of the control method can make your valves service life more longer, more convenient operation, cost savings.

 

Normally open type user: Suitable for pneumatic valve in the working time longer occasion. When the valve is normally open spring does not load external gas source thrust, then the valve fatigue to a minimum. Because it is by the air pressure to close valve, so need filed air pressure stability, air supply reliable.

 

Normally closed type user: Suitable for pneumatic valve is in the closed time working longer occasion. For depends on the spring to close, when air pressure to drive the piston push spring, valve open. So for the normally closed user this valve service life more long, gas more economical. At the same time when the air supply fails, the valve is in the closed state, this control state is the most widely used.

  

Double acting type user: Double acting type refers to the two chambers can be input compressed air separately, realize the two-way movement of the cylinder, no spring in the cylinder, the valve opening and closing rapidly, and can be used for large stroke valve, because it is by air pressure to close valve, so need the field gas source stability, air supply reliable. 






Pneumatic accessory






NO

1

2

3

4

Name

Positioner

Limit switch

Switch prompt feedback

Solenoid valve

Input signal

4-20Ma, 0-5v, 1-10v

 

 

AC220V; DC24V

Output signal

Optional: 4-20mA, 0-5v, 1-10v

Built-in two passive contact switch

Built-in float switch

 

Function

The remote flow control, temperature control

Feedback valve open and closed postion

Site operation beservation

Solenoid valve losing and get electricity, control the air reversing, realize the pneumatic valve switch.





Recommended products